University of Oxford Logo University of OxfordDepartment of Computer Science - Home

Pulmonary blood flow measured by inspiratory inert gas concentration forcing oscillations

EM Williams‚ MC Sainsbury‚ L. Sutton‚ L. Xiong‚ AMS Black‚ JP Whiteley‚ DJ Gavaghan and CEW Hahn

Abstract

The aim of this study was to discover if the forced inspired inert gas sinewave technique could be used to measure pulmonary blood flow, using nitrous oxide as the indicator gas, following inotropic stimulation of the heart by dobutamine, in the presence of a constant alveolar ventilation. Cardiac output (range 1-4.5 L min(-1)) was measured in six dogs by thermodilution and by calculation from the sinusoidal expired partial pressures of argon and nitrous oxide using: (i) analytical equations and a conventional continuous ventilation three-compartment lung model, which did not include recirculation; and

Details

Journal

RESPIRATION PHYSIOLOGY    

Keywords

exchange

Month

Jul

Number

1

Pages

47–56

Volume

113

Year

1998